Atlantic Testing Services (888) 696-6429
Palm Beach, Broward and Miami-Dade

Envelope testing that arrives licensed.

Nuclear moisture surveys, infrared thermography and electronic leak detection across South Florida.

3 test methods, one vendor, one mobilisation
FM Approved low-voltage ELD method
75,000+ leaks found

We are not local, and that is the point

Our crews travel to South Florida from New Jersey. Worth saying plainly, because you will find out on the phone anyway, and because it is bound up with the reason to hire us.

On a large roof or a plaza deck, the testing is a small fraction of the project. What it protects is the part that is not small: the tear-off you can avoid, the warranty that holds, the claim that never gets filed. Bringing in a specialist for a day or two is normal on work at that scale, and it is routine in specification-driven projects.

What is not routine is finding a firm that can bring all three test methods, and is licensed to bring the one that matters most in this climate.

The reason to fly someone in

We are licensed to run the nuclear gauge in Florida

A nuclear moisture gauge contains a sealed radioactive source. Operating one in Florida requires state licensing, which is a genuine regulatory barrier and not a box most testing firms have ever ticked. Of the competitors we have surveyed, only about three in eight carry nuclear at all, before licensing is even considered.

It matters here more than it does up north, and the reason is the roofs themselves. Florida commercial roofs get recovered and storm-repaired repeatedly, and every round adds a layer. What ends up on the building is a multi-layer assembly holding moisture somewhere inside it that a thermal scan cannot read through. Ballast and pavers defeat infrared outright.

That is the case nuclear exists for. It measures moisture within the insulation even beneath added membrane, which turns a roof nobody could properly assess into a roof with a defensible moisture map. A firm that owns only a thermal camera has to work with what the camera can see.

Our New Jersey radioactive materials licence is 1050897 - RAD250001, issued by the New Jersey Department of Environmental Protection and valid through 2034, with Todd Marcus named on it as Radiation Safety Officer. Florida work currently runs under temporary reciprocity while permanent state licensing is finalised.

Worth asking any agency that quotes you nuclear work for the same two things: the licence number and who issued it.

What we run in South Florida

Three methods, one mobilisation

Booked together they share a trip, which is the economical way to buy testing from an out-of-state agency.

Electronic leak detection
ASTM D7877 / D8231 · FM Approved

Finds the actual breach in a new or existing membrane, to the square inch, without flooding the structure. The close-out test on new work.

Nuclear moisture surveys
Licensed in Florida

Maps what is already wet inside the assembly, in daylight, regardless of weather. Reads through surfaces infrared cannot see past.

Infrared thermography
Envelope, electrical, mechanical, solar

Covers ground fast when conditions allow it. We will tell you honestly when they do not.

Air and vapor barrier testing
ASTM E1186

Verifies the barrier performs as specified while it is still exposed and can be corrected.

For architects and spec writers

If you are writing the testing into a South Florida job

Everything a specification needs is published: the standards, the scope language you can paste, the registration numbers and the qualification package. Most testing firms make you email for it.

We will also read a draft testing scope and tell you where it is loose enough for a low bidder to walk through, at no charge and with no obligation to name us.

Tell us about the building

The assembly, roughly how big, where it is, and what you are seeing. We will tell you which test it needs, or that it does not need one.