Atlantic Testing Services (888) 696-6429

Find the breach.
Before it becomes the claim.

We find where water is getting into a building, and where it already sits inside the roof.

75,000+leaks found
FM Approvedthe low-voltage ELD method we test with
Licensedto run the nuclear gauge, which most firms are not
What we are known for

Three tests that answer three different questions

Most of our work is one of these, and the hardest part of the job is knowing which one a building actually needs.

Electronic leak detection

Where is the hole?

Finds the actual breach in a membrane, to the square inch, without flooding anything. The Detec IntegriScan needs no perimeter wire and covers up to 40,000 square feet a day.

ASTM D7877 and D8231. FM Approved.

Infrared thermography

What is wet, and what else is failing?

Reads temperature across 100% of a roof to find saturated insulation, and off the roof it finds failing electrical connections before they fail.

ASTM C1153.

Nuclear moisture surveys

What can infrared not see?

Reads through ballast, cover boards and overlay after overlay, in daylight and in any weather. Licensed operators, which is a barrier most firms never clear.

NJ licence 1050897 - RAD250001.

We also perform air and vapor barrier testing to ASTM E1186 and D4541, verifying the barrier performs as specified while it is still exposed and can be corrected.

And a smaller amount of private utility locating, concrete scanning and water main leak detection.

How we work

We do not sell the repair we just recommended

A firm that sells roofs has a reason to find a roof that needs replacing. A firm that owns one instrument has a reason to recommend that instrument. Neither is dishonesty. It is what happens when the person diagnosing the problem also profits from the answer.

We only test. And we carry infrared and nuclear both, low voltage and high voltage both, so when we tell you which method your building needs, nothing rides on the answer. The report says what we found and stops there.

Expanding

Now working in South Florida

Palm Beach, Broward and Miami-Dade. Crews travel in from New Jersey, and the reason that is worth doing is the nuclear gauge.

Florida commercial roofs get recovered and storm-repaired until they become multi-layer assemblies that a thermal scan cannot read through. That is exactly the case nuclear exists for, and very few firms down there are licensed to run one.

Talk to someone who has been on the roof

Tell us the building, the assembly and what you are seeing. If testing is not the right answer, we will say so.